Listem REX-525R Specifications: CLASSIC
Floor-ceiling type radiator column
Column length – 2270 mm
Arm length – max. 1340 mm, min. 1,080 mm
Rail length – 3500 mm
Tube movement:
Vertical – 390 to 1890 mm (total 1500 mm)
Horizontal – 2450 mm
Tube rotation: ± 180°
Generator
Maximum generator power: 40 kW
Electricity range: 0.01 ~ 512 mAs
Anode voltage range: 40-125 kV
Minimum exposure time: 1ms – 10s
Organautomatics programs: 768 programs for radiography
Mains voltage: 220 V ± 10%, 50/60 Hz, 1 phase
Picture stand
Vertical movement – 1755 mm
Distance from cassette to surface – 32 mm
Minimum distance from the floor – 380 mm
Dimensions – 2140 x 770 x 500 mm

Radiographic table with floating detector
table can be moved in 4 directions for fast and easy patient positioning
Table can support up to 200 kg, while maintaining smooth motion of the top surface
Radiographic table is compatible with 18 cm x 24 cm (8 “x10”) and 43 cm x 43 cm (17 “x17”) cassettes and smaller
Crisp, clear images at longer radiographic distances due to expanded radiographic range
TOSHIBA X-ray tube
Maximum anode voltage of 125 kV;
-0.9 Al filtration
Type of anode – rotating;
Heat capacity of the anode – 140 kTU;
Large focal spot – 2 mm;
Small focal spot – 1 mm

Wireless digital flat panel detector (optional)
Rayence 1417 WCC detector model
Sensor material – Amorphous silicon
Scintillator type – Cesium-iodine
Image sensor size – 3328*2816 pixels
Pixel size – 127 μm
Working surface – 430*360 mm
Image size (W*H*D) – 386*460*15 mm
Quantum efficiency – not less than 50%
Image transfer time – up to 5 seconds
Connection type – Wireless
Battery capacity -3400 mAh
Cordless operation time – 4 hours
Charging time – 3 hours

$2,050.00

Category:

Description

Listem REX-525R Specifications: CLASSIC
Floor-ceiling type radiator column
Column length – 2270 mm
Arm length – max. 1340 mm, min. 1,080 mm
Rail length – 3500 mm
Tube movement:
Vertical – 390 to 1890 mm (total 1500 mm)
Horizontal – 2450 mm
Tube rotation: ± 180°
Generator
Maximum generator power: 40 kW
Electricity range: 0.01 ~ 512 mAs
Anode voltage range: 40-125 kV
Minimum exposure time: 1ms – 10s
Organautomatics programs: 768 programs for radiography
Mains voltage: 220 V ± 10%, 50/60 Hz, 1 phase
Picture stand
Vertical movement – 1755 mm
Distance from cassette to surface – 32 mm
Minimum distance from the floor – 380 mm
Dimensions – 2140 x 770 x 500 mm

Radiographic table with floating detector
table can be moved in 4 directions for fast and easy patient positioning
Table can support up to 200 kg, while maintaining smooth motion of the top surface
Radiographic table is compatible with 18 cm x 24 cm (8 “x10”) and 43 cm x 43 cm (17 “x17”) cassettes and smaller
Crisp, clear images at longer radiographic distances due to expanded radiographic range
TOSHIBA X-ray tube
Maximum anode voltage of 125 kV;
-0.9 Al filtration
Type of anode – rotating;
Heat capacity of the anode – 140 kTU;
Large focal spot – 2 mm;
Small focal spot – 1 mm

Wireless digital flat panel detector (optional)
Rayence 1417 WCC detector model
Sensor material – Amorphous silicon
Scintillator type – Cesium-iodine
Image sensor size – 3328*2816 pixels
Pixel size – 127 μm
Working surface – 430*360 mm
Image size (W*H*D) – 386*460*15 mm
Quantum efficiency – not less than 50%
Image transfer time – up to 5 seconds
Connection type – Wireless
Battery capacity -3400 mAh
Cordless operation time – 4 hours
Charging time – 3 hours